Do you need 5/8 fire-rated drywall in an Ottawa basement?
When the Ontario code needs a fire separation in a basement, when plain 1/2 inch is fine, how SB-3 rates each board, and what 5/8 and Level 5 change.
For an Ottawa basement, we recommend 5/8 Type X where a fire separation is required, and plain 1/2 inch is fine for the rest. The Building Code does not ask for 5/8 everywhere: the 2024 Building Code Compendium, Part 9 Housing and Small Buildings asks for a 45 min fire separation between suites (Article 9.10.9.16), so the board comes down to whether your basement is a separate suite.
Where no rating is required, the SB-3 table rates a 1/2 inch regular board wall on insulated wood studs at 30 min and a 5/8 Type X wall at 1 h. We have finished a whole house in 5/8 fire-rated board with a Level 5 finish. The thicker board changes the job: heavier sheets, deeper screws on a rated ceiling and, for Level 5, a skim coat over every surface.

When a basement needs a fire separation
Article 9.10.9.16 asks for a 45 min fire separation between suites. In a house with a secondary suite, the Code accepts 15.9 mm (5/8 inch) Type X on both sides of the walls and on the underside of the floor-ceiling framing, as a continuous smoke-tight barrier. Put simply, the fire-rated board goes on the walls that separate the two homes and across the ceiling between them, with no gaps for smoke. Where the house is sprinklered, the rating may be waived.
An attached garage is the other thing to check. Article 9.10.9.18 treats a garage that serves only its own house as part of that dwelling, with an air barrier between them in place of a fire separation. Our advice for both cases: check an attached garage or a secondary suite with the building department before choosing the board.
Where no rating is required
If the basement is part of your own home and not a separate suite, there is no suite separation to build, and plain 1/2 inch board is fine. The Supplementary Standard SB-3 Fire and Sound Resistance Tables list both boards for a wall on wood studs with insulation. On fire, 1/2 inch regular rates 30 min and 5/8 Type X rates 1 h. On sound, it is STC 32 against STC 36. STC is the sound transmission class: the higher the number, the less sound passes through the wall.
So 5/8 Type X does better on fire and on sound, but inside a single home the Code does not ask for either number. That is why we recommend 1/2 inch for a basement that is part of the house. We supply and hang the board on our drywall installation work in Ottawa, basements and new homes included.
What thicker board and a skim coat change in the work
Going thicker costs labour. The 5/8 board is heavier to lift and hang than 1/2 inch, on every wall and every ceiling.
A fire-rated ceiling also takes deeper screws. Table 9.29.5.5 in the 2024 Building Code Compendium, Part 9 Housing and Small Buildings asks for 30 mm of penetration into wood ceiling framing for 45 min and 45 mm for 1 h, against 15 mm where no rating is required.
Level 5 is a separate choice from the board. After the taping and fastener coats, a thin skim coat of joint compound is troweled over the entire surface. CGC's Gypsum Construction Handbook, Chapter 5 Finishing Drywall Systems calls for it where gloss, semigloss or enamel paint is specified or where critical lighting occurs, because it gives a uniform surface and hides joints and fasteners. Flat paint without critical lighting is not on that list. We do Level 5 as part of our drywall taping, mudding and Level 5 finishing work.
What would move us off plain 1/2 inch in a basement is a secondary suite. If the basement shares a wall with an attached garage, check that wall with the building department first.